Need Help? Call 704-288-2882  
   CED/MONROE   
View Cart CART  
 Shop by Category  ( Show All )

Back

Top Sellers in Distribution Equipt - Load Centers & S. E. Equipment

   
Show  items per page    First Previous  Page   of  3  Next Last
ARC FAULT CIRCUIT BREAKER
GE DISTRIBUTION EQUIPMENT
THQL1115AF2
15A PLUG IN AFCI CB
THERMAL MAGNETIC; 1 POLE; 120/240 VAC VOLTAGE RATING; 15 AMPERE CURRENT RATING; INTERRUPTING RATING 10 KILOAMPERE; BOX TERMINAL; WIRE SIZE 14 TO 10 AWG (COPPER/ALUMINUM); WITH ARC FAULT CIRCUIT INTERRUPTER; 1 INCH PLUG IN MOUNTING; SIZE 1 INCH W X 2 3/8 INCH D X 3 9/32 INCH H; APPROVAL UL 489, UL 1699; USED ON AL/ALC SERIES PANELBOARD, RESIDENTIAL LOAD CENTER; THQL MODEL

Show all:  Single Phase Main Breaker Load Centers

 More Details
32
ARC FAULT CIRCUIT BREAKER
GE DISTRIBUTION EQUIPMENT
THQL1120AF2
20A PLUG IN AFCI CB
THERMAL MAGNETIC; 1 POLE; 120/240 VAC VOLTAGE RATING; 20 AMPERE CURRENT RATING; INTERRUPTING RATING 10 KILOAMPERE; BOX TERMINAL; WIRE SIZE 14 TO 10 AWG (COPPER/ALUMINUM); WITH ARC FAULT CIRCUIT INTERRUPTER; 1 INCH PLUG IN MOUNTING; SIZE 1 INCH W X 2 3/8 INCH D X 3 9/32 INCH H; APPROVAL UL 489, UL 1699; USED ON AL/ALC SERIES PANELBOARD, RESIDENTIAL LOAD CENTER; THQL MODEL

Show all:  Single Phase Main Breaker Load Centers

 More Details
41
LOADCENTER
GE DISTRIBUTION EQUIPMENT
TM3220RCU
200A LD-CNTR
MAIN BREAKER; 120/240 VAC VOLTAGE RATING; 200 AMPERE CURRENT RATING; 40 MAXIMUM CIRCUIT(S); (32) 1 POLE 1 INCH THQL/(16) 2 POLE 1 INCH THQL/(16) 1 POLE 1/2 INCH THQP/(6) 2 POLE 1/2 INCH THQP MAXIMUM SPACE(S); THQL/THQP MAIN BREAKER; BREAKER MOUNTING PLUG IN; INTERRUPTING RATING 22 KILOAMPERE; SPLIT NEUTRAL; COPPER BUS MATERIAL; TOP FEED LOCATION; MAIN WIRE SIZE 1 AWG TO 250 KCMIL (COPPER), 2/0 AWG TO 250 KCMIL (ALUMINUM); NEMA 3R, OUTDOOR ENCLOSURE; ENCLOSURE SIZE DESIGNATION R7; SIZE 12 1/2 INCH W X 4 5/8 INCH D X 35 11/16 INCH H; APPROVAL UL; POWERMARK GOLD[T] BRAND

Show all:  Single Phase Main Breaker Load Centers

 Spec Sheet   |   More Details
2
LOADCENTER
GE DISTRIBUTION EQUIPMENT
TLM1212CCU
125A LD-CNTR
CONVERTIBLE MAIN; 120/240 VAC VOLTAGE RATING; 125 AMPERE CURRENT RATING; 24 MAXIMUM CIRCUIT(S); (12) 1 POLE 1 INCH THQL/(6) 2 POLE 1 INCH THQL/(24) 1 POLE 1/2 INCH THQP/(10) 2 POLE 1/2 INCH THQP MAXIMUM SPACE(S); THQL/THQP/THHQL/TXQL/TQMH MAIN BREAKER; BREAKER MOUNTING PLUG IN; INTERRUPTING RATING 22 KILOAMPERE; SPLIT NEUTRAL; COPPER BUS MATERIAL; TOP FEED LOCATION; MAIN WIRE SIZE 6 TO 2/0 AWG (ALUMINUM/COPPER); NEMA 1, INDOOR ENCLOSURE; FLUSH/SURFACE COVER; ENCLOSURE SIZE DESIGNATION 4; SIZE 14 INCH W X 3 3/4 INCH D X 19 INCH H; APPROVAL UL; POWERMARK GOLD[T] BRAND; ENCLOSURE MATERIAL GALVANIZED STEEL

Show all:  Single Phase Convertible Load Centers

 Spec Sheet   |   More Details
3
LOADCENTER
GE DISTRIBUTION EQUIPMENT
TM3220CCU
200A LD-CNTR
MAIN BREAKER; 120/240 VAC VOLTAGE RATING; 200 AMPERE CURRENT RATING; 40 MAXIMUM CIRCUIT(S); (32) 1 POLE 1 INCH THQL/(16) 2 POLE 1 INCH THQL/(16) 1 POLE 1/2 INCH THQP/(6) 2 POLE 1/2 INCH THQP MAXIMUM SPACE(S); THQL/THQP MAIN BREAKER; BREAKER MOUNTING PLUG IN; INTERRUPTING RATING 22 KILOAMPERE; SPLIT NEUTRAL; COPPER BUS MATERIAL; TOP/BOTTOM FEED LOCATION; MAIN WIRE SIZE 1 AWG TO 250 KCMIL (COPPER), 2/0 AWG TO 250 KCMIL (ALUMINUM); NEMA 1, INDOOR ENCLOSURE; FLUSH/SURFACE COVER; ENCLOSURE SIZE DESIGNATION 12; SIZE 14 INCH W X 3 3/4 INCH D X 35 7/16 INCH H; APPROVAL UL; POWERMARK GOLD[T] BRAND

Show all:  Single Phase Main Breaker Load Centers

 Spec Sheet   |   More Details
3
FILLER PLATE
GE DISTRIBUTION EQUIPMENT
TQLFP1
1-IN FILLER PLT
SIZE 1 INCH; USED ON A-SERIES[R] PANELBOARD, Q LINE/TEY CIRCUIT BREAKER; PACKAGING QUANTITY 50

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
20
UNIVERSAL RAINTIGHT HUB
GE DISTRIBUTION EQUIPMENT
TC200
2-IN UNIVERSAL HUB
ALUMINUM MATERIAL; RAIN TIGHT; 2 INCH CONDUIT; STANDARD PACKAGE 10; USED ON POWERMARK GOLD AND PLUS[T] LOAD CENTER; BASE SIZE 3 INCH

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
2
LOADCENTER
GE DISTRIBUTION EQUIPMENT
TLM2412CCU
125A LD-CNTR
CONVERTIBLE MAIN; 120/240 VAC VOLTAGE RATING; 125 AMPERE CURRENT RATING; 24 MAXIMUM CIRCUIT(S); (24) 1 POLE 1 INCH THQL/(12) 2 POLE 1 INCH THQL MAXIMUM SPACE(S); THQL/THHQL/TXQL/TQMH MAIN BREAKER; BREAKER MOUNTING PLUG IN; INTERRUPTING RATING 22 KILOAMPERE; SPLIT NEUTRAL; COPPER BUS MATERIAL; TOP/BOTTOM FEED LOCATION; MAIN WIRE SIZE 6 TO 2/0 AWG (ALUMINUM/COPPER); NEMA 1, INDOOR ENCLOSURE; FLUSH/SURFACE COVER; ENCLOSURE SIZE DESIGNATION 7; SIZE 14 INCH W X 3 3/4 INCH D X 24 11/16 INCH H; APPROVAL UL; POWERMARK GOLD[T] BRAND; ENCLOSURE MATERIAL GALVANIZED STEEL

Show all:  Single Phase Convertible Load Centers

 Spec Sheet   |   More Details
2
LOADCENTER
GE DISTRIBUTION EQUIPMENT
TLM812RCU
125A LD-CNTR
CONVERTIBLE MAIN; 120/240 VAC VOLTAGE RATING; 125 AMPERE CURRENT RATING; 16 MAXIMUM CIRCUIT(S); (8) 1 POLE 1 INCH THQL/(4) 2 POLE 1 INCH THQL/(16) 1 POLE 1/2 INCH THQP/(8) 2 POLE 1/2 INCH THQP MAXIMUM SPACE(S); THQL/THQP MAIN BREAKER; BREAKER MOUNTING PLUG IN; INTERRUPTING RATING 22 KILOAMPERE; SPLIT NEUTRAL; COPPER BUS MATERIAL; TOP FEED LOCATION; MAIN WIRE SIZE 6 TO 3 AWG (ALUMINUM/COPPER); NEMA 3R, OUTDOOR ENCLOSURE; ENCLOSURE SIZE DESIGNATION R2A; SIZE 11 1/4 INCH W X 3 1/4 INCH D X 11 1/8 INCH H; APPROVAL UL; POWERMARK GOLD[T] BRAND; ENCLOSURE MATERIAL GALVANIZED STEEL

Show all:  Single Phase Convertible Load Centers

 Spec Sheet   |   More Details
3
LOADCENTER
GE DISTRIBUTION EQUIPMENT
TM820RCUFL
200A LD-CNTR
MAIN BREAKER; 120/240 VAC VOLTAGE RATING; 200 AMPERE CURRENT RATING; 16 MAXIMUM CIRCUIT(S); (8) 1 POLE 1 INCH THQL/(4) 2 POLE 1 INCH THQL/(16) 1 POLE 1/2 INCH THQP/(6) 2 POLE 1/2 INCH THQP MAXIMUM SPACE(S); THQL/THQP MAIN BREAKER; BREAKER MOUNTING PLUG IN; INTERRUPTING RATING 22 KILOAMPERE; SPLIT NEUTRAL; COPPER BUS MATERIAL; TOP FEED LOCATION; MAIN WIRE SIZE 1 AWG TO 250 KCMIL (COPPER), 2/0 AWG TO 250 KCMIL (ALUMINUM); NEMA 3R, OUTDOOR ENCLOSURE; ENCLOSURE SIZE DESIGNATION R5; SIZE 12 1/2 INCH W X 4 5/8 INCH D X 28 11/16 INCH H; APPROVAL UL; POWERMARK PLUS[T] BRAND; WITH FEED THROUGH LUGS

Show all:  Single Phase Main Breaker Load Centers

 Spec Sheet   |   More Details
10
LOADCENTER
GE DISTRIBUTION EQUIPMENT
TL18420C
200A LD-CNTR
MAIN LUG; 208 VAC STAR/120 VAC VOLTAGE RATING; 200 AMPERE CURRENT RATING; 18 MAXIMUM CIRCUIT(S); (18) 1 POLE 1 INCH THQL/(8) 2 POLE 1 INCH THQL/(6) 3 POLE 1 INCH THQL MAXIMUM SPACE(S); BREAKER MOUNTING PLUG IN; INTERRUPTING RATING 22 KILOAMPERE; SPLIT NEUTRAL; TOP/BOTTOM FEED LOCATION; MAIN WIRE SIZE 1 AWG TO 250 KCMIL (COPPER), 2/0 AWG TO 250 KCMIL (ALUMINUM); NEMA 1, INDOOR ENCLOSURE; FLUSH/SURFACE COVER; ENCLOSURE SIZE DESIGNATION 7; SIZE 14 INCH W X 3 3/4 INCH D X 24 11/16 INCH H; APPROVAL UL; POWERMARK PLUS[T] BRAND

Show all:  Three Phase Main Lug Load Centers

 Spec Sheet   |   More Details
2
LOADCENTER
GE DISTRIBUTION EQUIPMENT
TLM1212RCU
125A LD-CNTR
CONVERTIBLE MAIN; 120/240 VAC VOLTAGE RATING; 125 AMPERE CURRENT RATING; 24 MAXIMUM CIRCUIT(S); (12) 1 POLE 1 INCH THQL/(6) 2 POLE 1 INCH THQL/(24) 1 POLE 1/2 INCH THQP/(10) 2 POLE 1/2 INCH THQP MAXIMUM SPACE(S); THQL/THQP/THHQL/TXQL/TQMH MAIN BREAKER; BREAKER MOUNTING PLUG IN; INTERRUPTING RATING 22 KILOAMPERE; SPLIT NEUTRAL; COPPER BUS MATERIAL; TOP FEED LOCATION; MAIN WIRE SIZE 6 TO 2/0 AWG (ALUMINUM/COPPER); NEMA 3R, OUTDOOR ENCLOSURE; ENCLOSURE SIZE DESIGNATION R3; SIZE 12 1/2 INCH W X 4 5/8 INCH D X 21 3/16 INCH H; APPROVAL UL; POWERMARK GOLD[T] BRAND; ENCLOSURE MATERIAL GALVANIZED STEEL

Show all:  Single Phase Convertible Load Centers

 Spec Sheet   |   More Details
1
LOADCENTER
GE DISTRIBUTION EQUIPMENT
TLM1220RCU
200A 1PH 3W LD-CNTR
CONVERTIBLE MAIN; 120/240 VAC VOLTAGE RATING; 200 AMPERE CURRENT RATING; 24 MAXIMUM CIRCUIT(S); (12) 1 POLE 1 INCH THQL/(6) 2 POLE 1 INCH THQL/(24) 1 POLE 1/2 INCH THQP/(10) 2 POLE 1/2 INCH THQP MAXIMUM SPACE(S); THQL/THQP MAIN BREAKER; BREAKER MOUNTING PLUG IN; INTERRUPTING RATING 22 KILOAMPERE; SPLIT NEUTRAL; COPPER BUS MATERIAL; TOP FEED LOCATION; MAIN WIRE SIZE 1 AWG TO 250 KCMIL (COPPER), 2/0 AWG TO 250 KCMIL (ALUMINUM); NEMA 3R, OUTDOOR ENCLOSURE; ENCLOSURE SIZE DESIGNATION R5; SIZE 12 1/2 INCH W X 4 5/8 INCH D X 28 11/16 INCH H; APPROVAL UL; POWERMARK GOLD[T] BRAND; ENCLOSURE MATERIAL GALVANIZED STEEL

Show all:  Single Phase Convertible Load Centers

 Spec Sheet   |   More Details
2
GROUND BUS BAR
GE DISTRIBUTION EQUIPMENT
TGK12
12H GROUND BAR KIT
CONDUCTOR MATERIAL ALUMINUM/COPPER; 12 TERMINAL (12 TO 10 AWG ALUMINUM SOLID/STRANDED OR 14 TO 4 AWG COPPER SOLID/STRANDED); USED ON POWERMARK PLUS[T]/POWERMARK GOLD[T] LOADCENTER; TGK MODEL; PACKAGING QUANTITY 1

Show all:  Load Center Accessories

 More Details
7
LOADCENTER
GE DISTRIBUTION EQUIPMENT
TLM612SCUD
125A LD-CNTR
CONVERTIBLE MAIN; 120/240 VAC VOLTAGE RATING; 125 AMPERE CURRENT RATING; 12 MAXIMUM CIRCUIT(S); (6) 1 POLE 1 INCH THQL/(3) 2 POLE 1 INCH THQL/(12) 1 POLE 1/2 INCH THQP/(6) 2 POLE 1/2 INCH THQP MAXIMUM SPACE(S); THQL/THQP MAIN BREAKER; BREAKER MOUNTING PLUG IN; INTERRUPTING RATING 22 KILOAMPERE; SPLIT NEUTRAL; COPPER BUS MATERIAL; TOP/BOTTOM FEED LOCATION; MAIN WIRE SIZE 6 TO 3 AWG (ALUMINUM/COPPER); NEMA 1, INDOOR ENCLOSURE; SURFACE WITH DOOR COVER; ENCLOSURE SIZE DESIGNATION 3A; SIZE 11 9/16 INCH W X 3 3/8 INCH D X 11 3/8 INCH H; APPROVAL UL; POWERMARK GOLD[T] BRAND; ENCLOSURE MATERIAL GALVANIZED STEEL

Show all:  Single Phase Convertible Load Centers

 Spec Sheet   |   More Details
2
* E=Each, C=100, M=1000
First Previous  Page   of  3  Next Last
 
 


1413 WALKUP AVENUE MONROE, NC 28110 | Tel: 704-288-2882 | Fax: 704-288-2883 | customerservice@cedmonroe.com
Terms of Use | Terms and Conditions
3.5.4