Top Sellers in Distribution Equipt - Safety Switches

   
Show  items per page    First Previous  Page   of  3  Next Last
AIR CONDITIONER DISCONNECT SWITCH
GE DISTRIBUTION EQUIPMENT
TFN60R
60A DISCONN SW
AIR CONDITIONER DISCONNECT; 240 VAC VOLTAGE RATING; 60 AMPERE CURRENT RATING; POWER RATING 10 HP; NON FUSIBLE FUSE; NEMA 3R ENCLOSURE; STEEL ENCLOSURE; WIRE SIZE 14 TO 3 AWG (COPPER/ALUMINUM); SIZE 4 3/4 INCH W X 2 INCH D X 7 1/2 INCH H; APPROVAL UL 1429; SPEC-SETTER[T] BRAND

Show all:  Non-Fusible Disconnect Safety Switches

 More Details
204
EQUIPMENT GROUND KIT
GE DISTRIBUTION EQUIPMENT
TGL1
7 TERM GRND KIT
EQUIPMENT GROUND LUG KIT; SWITCH VOLTAGE RATING 240/600 V; SWITCH CURRENT RATING 70 TO 125 AMPERE; WIRE SIZE (4) 12 TO 8 AWG ((ALUMINUM), (4) 14 TO 8 AWG (COPPER), (3) 6 TO 4 AWG (ALUMINUM), (3) 14 TO 4 AWG (COPPER); USED ON SPEC-SETTER[T] TC SERIES NON FUSIBLE DOUBLE THROW SAFETY SWITCH; TG MODEL; STANDARD PACKAGING QUANTITY 20

Show all:  Safety Switch Accessories

 Spec Sheet   |   More Details
8
SAFETY SWITCH
GE DISTRIBUTION EQUIPMENT
TH3361
30A-600V-3P SW
HEAVY DUTY; 480 V STAR/277 V, 480/600 VAC AC VOLTAGE; 250 V DC VOLTAGE; 30 AMPERE CURRENT RATING; POWER RATING 5 HP AT 480 VAC 3 PHASE, 7 1/2 HP AT 600 VAC 3 PHASE (STANDARD); 15 HP AT 480 VAC 3 PHASE, 20 HP AT 600 VAC 3 PHASE (TIME DELAY); 5 HP AT 250 VDC; 3 POLE; 3 WIRE; CARTRIDGE, CLASS H/J/R FUSE; FUSIBLE FUSE; NO NEUTRAL; NEMA 1 ENCLOSURE; SIZE 9 1/2 INCH W X 4 INCH D X 12 5/8 INCH H; APPROVAL UL 98, CSA; SPEC-SETTER[T] BRAND; TH MODEL

Show all:  Fusible Heavy Duty Safety Switches

 More Details
3
SAFETY SWITCH
GE DISTRIBUTION EQUIPMENT
TGN3321R
30A-240V-3P SW
GENERAL DUTY; 240 V AC VOLTAGE; 250 V DC VOLTAGE; 30 AMPERE CURRENT RATING; POWER RATING 3 HP AT 240 VAC 1 PHASE, 7 1/2 HP AT 240 VAC 3 PHASE (STANDARD); 3 HP AT 240 VAC 1 PHASE, 7 1/2 HP AT 240 VAC 3 PHASE (TIME DELAY); 5 HP AT 250 VDC; 3 POLE; 3 WIRE; CARTRIDGE, CLASS H/K/R FUSE; NON FUSIBLE FUSE; SWITCHING NEUTRAL; NEMA 3R ENCLOSURE; SIZE 7 1/4 INCH W X 3 5/16 INCH D X 9 7/8 INCH H; APPROVAL UL 98, CSA; SPEC-SETTER[T] BRAND; TG MODEL

Show all:  Non-Fusible General Duty Safety Switches

 More Details
3
SAFETY SWITCH
GE DISTRIBUTION EQUIPMENT
TG4322R
60A-240V-3P SW
GENERAL DUTY; 208 V STAR/120 V, 240 VAC AC VOLTAGE; 250 V DC VOLTAGE; 60 AMPERE CURRENT RATING; POWER RATING 3 HP AT 240 VAC 1 PHASE, 7 1/2 HP AT 240 VAC 3 PHASE (STANDARD); 10 HP AT 240 VAC 1 PHASE, 15 HP AT 240 VAC 3 PHASE (TIME DELAY); 3 HP AT 125 VDC, 10 HP AT 250 VDC; 3 POLE; 4 WIRE; CARTRIDGE, CLASS H/K/R FUSE; FUSIBLE FUSE; NO NEUTRAL; NEMA 3R ENCLOSURE; SIZE 9 1/4 INCH W X 4 INCH D X 13 3/4 INCH H; APPROVAL UL 98, CSA; SPEC-SETTER[T] BRAND; TG MODEL

Show all:  Fusible General Duty Safety Switches

 More Details
2
SAFETY SWITCH
GE DISTRIBUTION EQUIPMENT
TH3364R
200A-600V-3P SW
HEAVY DUTY; 480 V STAR/277 V, 480/600 VAC AC VOLTAGE; 250 V DC VOLTAGE; 200 AMPERE CURRENT RATING; POWER RATING 50 HP AT 480 VAC 3 PHASE, 60 HP AT 600 VAC 3 PHASE (STANDARD); 125 HP AT 480 VAC 3 PHASE, 150 HP AT 600 VAC 3 PHASE (TIME DELAY); 40 HP AT 250 VDC; 3 POLE; 3 WIRE; CARTRIDGE, CLASS H/J/R FUSE; FUSIBLE FUSE; NO NEUTRAL; NEMA 3R ENCLOSURE; SIZE 14 1/8 INCH W X 5 5/16 INCH D X 31 1/2 INCH H; APPROVAL UL 98, CSA; SPEC-SETTER[T] BRAND; TH MODEL

Show all:  Fusible Heavy Duty Safety Switches

 More Details
2
EQUIPMENT GROUND KIT
GE DISTRIBUTION EQUIPMENT
TNG3
3 TERM GRND KIT
EQUIPMENT GROUND LUG KIT; SWITCH VOLTAGE RATING 240/600 V; SWITCH CURRENT RATING 400/600 AMPERE; WIRE SIZE (3) 10 TO 1/0 AWG (ALUMINUM/COPPER); USED ON SPEC-SETTER[T] TC SERIES NON FUSIBLE DOUBLE THROW SAFETY SWITCH; TN MODEL; STANDARD PACKAGING QUANTITY 1

Show all:  Safety Switch Accessories

 Spec Sheet   |   More Details
10
SAFETY SWITCH
GE DISTRIBUTION EQUIPMENT
TG3222
60A-240V-2P SW
GENERAL DUTY; 120/240 V AC VOLTAGE; 250 V DC VOLTAGE; 60 AMPERE CURRENT RATING; POWER RATING 3 HP AT 240 VAC 1 PHASE, 7 1/2 HP AT 240 VAC 3 PHASE (STANDARD); 10 HP AT 240 VAC 1 PHASE, 15 HP AT 240 VAC 3 PHASE (TIME DELAY); 3 HP AT 125 VDC, 10 HP AT 250 VDC; 2 POLE; 3 WIRE; CARTRIDGE, CLASS H/K/R FUSE; FUSIBLE FUSE; NO NEUTRAL; NEMA 1 ENCLOSURE; SIZE 9 INCH W X 4 INCH D X 13 7/8 INCH H; APPROVAL UL 98, CSA; SPEC-SETTER[T] BRAND; TG MODEL

Show all:  Fusible General Duty Safety Switches

 More Details
2
SAFETY SWITCH
GE DISTRIBUTION EQUIPMENT
TH3363R
100A-600V-3P SW
HEAVY DUTY; 480 V STAR/277 V, 480/600 VAC AC VOLTAGE; 250 V DC VOLTAGE; 100 AMPERE CURRENT RATING; POWER RATING 25 HP AT 480 VAC 3 PHASE, 30 HP AT 600 VAC 3 PHASE (STANDARD); 60 HP AT 480 VAC 3 PHASE, 75 HP AT 600 VAC 3 PHASE (TIME DELAY); 20 HP AT 250 VDC; 3 POLE; 3 WIRE; CARTRIDGE, CLASS H/J/R FUSE; FUSIBLE FUSE; NO NEUTRAL; NEMA 3R ENCLOSURE; SIZE 10 5/8 INCH W X 5 INCH D X 22 1/4 INCH H; APPROVAL UL 98, CSA; SPEC-SETTER[T] BRAND; TH MODEL

Show all:  Fusible Heavy Duty Safety Switches

 More Details
2
SAFETY SWITCH
GE DISTRIBUTION EQUIPMENT
TH3221R
30A-240V-2P SW
HEAVY DUTY; 120/240 V AC VOLTAGE; 250 V DC VOLTAGE; 30 AMPERE CURRENT RATING; POWER RATING 1 1/2 HP AT 240 VAC 1 PHASE, 3 HP AT 240 VAC 3 PHASE (STANDARD); 3 HP AT 240 VAC 1 PHASE, 7 1/2 HP AT 240 VAC 3 PHASE (TIME DELAY); 5 HP AT 250 VDC; 2 POLE; 3 WIRE; CARTRIDGE, CLASS H/J/R FUSE; FUSIBLE FUSE; NO NEUTRAL; NEMA 3R ENCLOSURE; SIZE 7 1/8 INCH W X 3 5/16 INCH D X 10 5/8 INCH H; APPROVAL UL 98, CSA; SPEC-SETTER[T] BRAND; TH MODEL

Show all:  Fusible Heavy Duty Safety Switches

 More Details
9
SAFETY SWITCH
GE DISTRIBUTION EQUIPMENT
TH3363
100A-600V-3P SW
HEAVY DUTY; 480 V STAR/277 V, 480/600 VAC AC VOLTAGE; 250 V DC VOLTAGE; 100 AMPERE CURRENT RATING; POWER RATING 25 HP AT 480 VAC 3 PHASE, 30 HP AT 600 VAC 3 PHASE (STANDARD); 60 HP AT 480 VAC 3 PHASE, 75 HP AT 600 VAC 3 PHASE (TIME DELAY); 20 HP AT 250 VDC; 3 POLE; 3 WIRE; CARTRIDGE, CLASS H/J/R FUSE; FUSIBLE FUSE; NO NEUTRAL; NEMA 1 ENCLOSURE; SIZE 10 1/8 INCH W X 5 INCH D X 22 3/4 INCH H; APPROVAL UL 98, CSA; SPEC-SETTER[T] BRAND; TH MODEL

Show all:  Fusible Heavy Duty Safety Switches

 More Details
1
EQUIPMENT GROUND KIT
GE DISTRIBUTION EQUIPMENT
TGL6
LUG KIT
EQUIPMENT GROUND LUG KIT; SWITCH VOLTAGE RATING 240/600 V; SWITCH CURRENT RATING 600 TO 1200 AMPERE; WIRE SIZE (3) 2 AWG TO 250 KCMIL (ALUMINUM/COPPER); USED ON SPEC-SETTER[T] TC SERIES NON FUSIBLE DOUBLE THROW SAFETY SWITCH; TG MODEL; STANDARD PACKAGING QUANTITY 1

Show all:  Safety Switch Accessories

 Spec Sheet   |   More Details
1
SAFETY SWITCH
GE DISTRIBUTION EQUIPMENT
THN3363
100A-600V-3PNF SW
HEAVY DUTY; 480/600 V AC VOLTAGE; 250 V DC VOLTAGE; 100 AMPERE CURRENT RATING; POWER RATING 20 HP AT 240 VAC 1 PHASE, 40 HP AT 240 VAC 3 PHASE (STANDARD); 75 HP AT 480 VAC 3 PHASE, 100 HP AT 600 VAC 3 PHASE (TIME DELAY); 20 HP AT 250 VDC; 3 POLE; 3 WIRE; CARTRIDGE, CLASS H/J/R FUSE; NON FUSIBLE FUSE; NO NEUTRAL; NEMA 1 ENCLOSURE; SIZE 10 1/8 INCH W X 5 INCH D X 17 5/8 INCH H; APPROVAL UL 98, CSA; SPEC-SETTER[T] BRAND; TH MODEL

Show all:  Non-Fusible Heavy Duty Safety Switches

 More Details
1
SAFETY SWITCH
GE DISTRIBUTION EQUIPMENT
TH3362
60A-600V-3P SW
HEAVY DUTY; 480 V STAR/277 V, 480/600 VAC AC VOLTAGE; 250 V DC VOLTAGE; 60 AMPERE CURRENT RATING; POWER RATING 15 HP AT 480 VAC 3 PHASE (STANDARD); 15 HP AT 600 VAC 3 PHASE (STANDARD); 30 HP AT 480 VAC 3 PHASE (TIME DELAY); 50 HP AT 600 VAC 3 PHASE (TIME DELAY); 10 HP AT 250 VDC; 3 POLE; 3 WIRE; CARTRIDGE, CLASS H/J/R FUSE; FUSIBLE FUSE; NO NEUTRAL; NEMA 1 ENCLOSURE; SIZE 10 1/8 INCH W X 5 INCH D X 21 3/8 INCH H; APPROVAL UL 98, CSA; SPEC-SETTER[T] BRAND; TH MODEL

Show all:  Fusible Heavy Duty Safety Switches

 More Details
1
SAFETY SWITCH
GE DISTRIBUTION EQUIPMENT
TGN3322R
60A-240V-3P SW
GENERAL DUTY; 240 V AC VOLTAGE; 250 V DC VOLTAGE; 60 AMPERE CURRENT RATING; POWER RATING 10 HP AT 240 VAC 1 PHASE, 15 HP AT 240 VAC 3 PHASE (STANDARD); 10 HP AT 240 VAC 1 PHASE, 15 HP AT 240 VAC 3 PHASE (TIME DELAY); 3 HP AT 125 VDC, 10 HP AT 250 VDC; 3 POLE; 3 WIRE; CARTRIDGE, CLASS H/K/R FUSE; NON FUSIBLE FUSE; SWITCHING NEUTRAL; NEMA 3R ENCLOSURE; SIZE 9 1/4 INCH W X 4 INCH D X 13 3/4 INCH H; APPROVAL UL 98, CSA; SPEC-SETTER[T] BRAND; TG MODEL

Show all:  Non-Fusible General Duty Safety Switches

 More Details
3